您好,欢迎您来到格朗瑞生物科技公司网站!
[登录]
[注册]
  • Content

ProZyme/GlykoPrep? H Cleanup Module (24-ct) [GS24-HC]/GS24-HC/1 ea

配件
ProZyme/GlykoPrep? H Cleanup Module (24-ct) [GS24-HC]/GS24-HC/1 ea


商品编号


GS24-HC



品牌


ProZyme



公司


ProZyme, Inc



公司分类


GlykoPrep?



Size

1 ea

商品信息

Description

GlykoPrep HC cartridges are solid-phase extraction spin cartridges, packed with ~5 mg of Hypercarb? porous graphitic carbon (PGC), designed for purification of glycans from non-carbohydrate material, including salts and proteins. When samples are loaded on the column, salts pass through, while glycans and protein adsorb onto the matrix. The glycans may then be selectively eluted from the column.

Applications:


Desalting of N-glycans released by native digestion with e.g. PNGase F

Protein removal and desalting following exoglycosidase digestion of released glycans (e.g. sialidase digestion, fucosidase digestion prior to 2-AB labeling)

Cleanup of glycans released by hydrazinolysis

Desalting glycan samples including anionic species prior to mass spectrometry

Cleanup of fluorescently-labeled glycans (e.g. glycans labeled with 2-AB, InstantAB?) from labeling reactions*


Note: these cartridges are not suitable for removing detergent.

*Not recommended for cleanup of InstantPC-labeled N-glycans, as these must be stored in Gly-X/InstantPC Eluent with 10% ACN. Samples applied to HC cartridges must be aqueous or low organic (<5%).

Sample prep considerations:

? Glycan samples to be cleaned must be in an aqueous buffer or a buffer containing a low percentage (<5%) of organic solvent.
? If the sample contains organic solvent, dilute with water until the organic solvent content is less than 5% by volume. For example, dilute a 5 μl 2-AB labeling reaction with 95 μl water prior to lo
ADI
ng.
? Samples should not contain detergents such as SDS.
? Suggested starting upper limit for the HC cartridges is ~50 μg glycans. The binding capacity for specific glycoproteins & glycans may need to be determined. Minimum glycan load will depend on the sensitivity of the analytical methods used.

T
he H Cleanup Module requires minimal equipment. All you need is a centrifuge with a deep-well plate rotor (minimum 44 mm height) and a Starter Labware Kit (
AM200
).

Alternatively, the cartridges may be run in a microcentrifuge using
Eppendorf
tubes and
AM400
adapters - please see the
User Manual
for details.

Contains


1 ea WS0317-24 H Cleanup (HC) Cartridges


Size:
1 ea

Product Code:
GS24-HC

上一篇 ProZyme/Enzymatic Deglycosylation Kit for N-Linked & Simple O-Linked Glycans [GK80110]/GK80110/1 Kit  下一篇 ProZyme/GlykoPrep?-plus Rapid N-Glycan Sample Preparation with InstantPC (96-ct) [GPPNG-PC]/GPPNG-PC/1 Kit

产品货号:6900.0

6900.0 ¥
11至15个工作日送达